Motor Forward / Reverse Control Board Two Relay Delay Timing Cycle Module

١١٩٫٠٠ ر.س.‏
والشحن مجاناً

Motor Forward / Reverse Control Board Two Relay Delay Timing Cycle Module

  • العلامة التجارية: Unbranded

Motor Forward / Reverse Control Board Two Relay Delay Timing Cycle Module

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ١٥٩٫٠٠ ر.س.‏
السعر: ١١٩٫٠٠ ر.س.‏
أنت توفر: ٤٠٫٠٠ ر.س.‏ (25%)
البائع:
١١٩٫٠٠ ر.س.‏
والشحن مجاناً

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Features 1、Brand new and high quality 2、6 kinds of commonly used functions to meet the needs of more applications; 3、It can control 2‑way solenoid valve, pumps, motors, lights and other running freely 4、Output power: it can control within 30A DC or AC load 5、Time range: 0.1 seconds to 999 minutes any time adjustable Specification Features: Brand new and high quality 6 kinds of commonly used functions to meet the needs of more applications; It can control 2-way solenoid valve, pumps, motors, lights and other running freely Output power: it can control within 30A DC or AC load Time range: 0.1 seconds to 999 minutes any time adjustable Specification: Time range: 0.1 seconds to 999 minutes Weight: Approx.110g/3.9oz Wiring port Description: 3. IN1: Signal input 1 (negative trigger) 4. IN2: Signal input terminal 2 (negative trigger) 2. IN3: Signal input 3 (negative trigger) 5. NO: relay normally open interface, relay pull before the suspension, after the connection with the COM shorted 6. COM: relay common interface 7. NC: relay normally closed interface, the relay before the connection with the COM shorted, pull after the suspension Function list: P - 1: to signal 1, relay 1 pulls to A time automatically stops; to signal 2, relay 2 pulls to B time automatically stops; signal 3 is emergency stop reset signal P - 2: signal 1, relay 1 is pulled to A time automatically stop; relay 2 from the signal to start delay B time after the suction to C time automatically stop (this function time unit needs to be consistent) P - 3: After power on, relay 1 pulls up to A time release, waiting for C time, relay 2 pulls to B time release, waits for C time; relay 1,2 turns endless operation endless cycle (If the control motor is reversible can be understood as: the motor is running a period of time; stop for some time; automatically reverse for some time; stop for some time; then automatically forward; P - 4: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stops and starts counting to A time relay 2 pull; to signal 3 (limit), relay 2 stops and starts timing To B time relay 1 pull; infinite loop (If the control motor is reversible can be understood as: press the start button 1; the motor is moving to the limit 2 to stop for a period of time; automatically reverse to the limit 3 to stop a period of time; then automatically forward; P - 5: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stop and start timing to A time relay 2 pull; give signal 3 (limit), relay 2 stop; Signal 1; once again (If the control motor is reversible can be understood as: press the start button 1; the motor is moving to the limit 2 to stop for a period of time; automatically reverse to the limit 3 stop; give the signal 1; P-6: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stop; give signal 1, relay 2 pull; to signal 3 (limit), relay 2 stop; (If the control motor is reversible can be understood as: press the start button 1; go to the limit 2 stop; press the start button 1 again; reverse to the limit 3 stop; If the remote control function: remote control A key and B key to start the above function; C key press the relay 1 work (forward); then press the relay 1 to stop (stop); D key press the relay 2 work (reverse); Press once relay 2 to stop (stop); Key Settings Description: Power display "----" that access to standby; Press the first time K1, the screen shows: P-1: K2 and K3 adjustment mode Press the second time K1, the screen shows: A001: K2 and K3 adjust the first time A, K4 adjust the decimal point (time unit) Press the third time K1, the screen shows: B001: K2 and K3 adjust the second time B, K4 adjust the decimal point (time unit) Press the fourth time K1, the screen shows: C001: K2 and K3 adjust the third time C, K4 adjust the decimal point (time unit) Press the fifth K1, display "----" that entered the standby state; For example; need to set the mode: P - 2; time: A010 B005 C006: Indicating the second mode of operation; after the signal 1; relay 1 after 10 seconds to start off; relay 2 to give the signal after delay 5 seconds after the start 1 second automatically shut down Decimal time unit Description: XX.X decimal point in the ten, timing range: 0.1 seconds to 99.9 seconds XXX no decimal point, timing range: 1 second to 999 seconds XXX. Decimal points in a single, timing range: 1 minute to 999 minutes Package list: 1 x Motor Control Board Package List
  • هوية Fruugo: 339985280-745790841
  • EAN: 6117160241274

معلومات سلامة المنتج

يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

ملصقات سلامة المنتج

CE Mark
تحذيرات السلامة: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

التسليم والرد

يُرسل خلال ٢ أيام

  • STANDARD: مجاناً - التسليم بين الخميس 09 أكتوبر 2025 – الأربعاء 15 أكتوبر 2025 - مجاناً

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة