5V-24V Motor Forward/Reverse Controller with Delay Timer, 8x5cm

٤٧٫٩٥ ر.س.‏
+ ١٥٫٩٩ ر.س.‏ الشحن

5V-24V Motor Forward/Reverse Controller with Delay Timer, 8x5cm

  • العلامة التجارية: Unbranded

5V-24V Motor Forward/Reverse Controller with Delay Timer, 8x5cm

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ٧٤٫٠٠ ر.س.‏
السعر: ٤٧٫٩٥ ر.س.‏
أنت توفر: ٢٦٫٠٥ ر.س.‏ (35%)
البائع:
٤٧٫٩٥ ر.س.‏
+ ١٥٫٩٩ ر.س.‏ الشحن

في المخزون

نقبل وسائل الدفع الآتية

الوصف

5V - 24V Motor Forward / Reverse Controller Timing Delay Time Cycles Relay Features: Dual power supply (two power supplies cannot be powered at the same time): Power supply 1, DC 6.5-25V; Power supply 2, DC 5V    Working current: (Normal Mode) standby current 41mA, working current 83mA; (Energy-Saving mode) Standby current 7mA, working current 44mA.    There are three input control port: forward control(FWD), reverse control(REV), and stop control(STOP).    Two input trigger modes, Low-Pulse trigger mode, Low-Level trigger mode    Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes.    Cycle times: no cycle, 2-99 cycles, always cycle.    Three indicators: forward indicator(F LED), reverse indicator(R LED), stop indicator(S LED).    Relay load current, recommended less than 5A. This is a multi-function DC/AC motor forward and reverse controller with multiple control modes. Many control functions can be derived through reasonable settings. Port:       DC 5.5MM female : Power supply 1, DC 5V power supply.  VIN: Power 2 positive, DC 6.5-25V power supply  GND: Power supply 2 negative  FWD: Forward input control (partial Function-Mode is invalid)  REV: Reverse input control (partial Function-Mode is invalid)  STOP : Stop input control (partial Function-Mode is invalid)  M+: Motor positive   M-: Motor negative  P+: Positive terminal for motor power supply P-: negative terminal for motor power supply   Specification: Power supply: DC 6.5-25V, DC 5V Working current: 83mA Standby current: 41mA Relay load current: <5A Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes Size: 8*5cm/3.2*2in Weight: Approx. 51g/1.8oz Trigger mode:  1 low pulse trigger (falling edge trigger) 2 low level trigger (rising edge trigger)     Timer:  T1: Forward timer T2: Reverse timer T3: Stop timer Time unit : 0.1 second, 1 second, 1 minute     Relay action:  Motor forward : Relay 1 is ON, relay 2 is OFF, and the F LED indicator is flashing. Motor reverse : Relay 1 is OFF, relay 2 is ON, and the R LED indicator is flashing.. Motor stop   : Relay 1 is OFF, relay 2 is OFF, and the S LED indicator is flashing.     Factory settings:  Press the "++" and "--" buttons simultaneously for 5 seconds.     Energy-saving mode:  Press and hold the "OK" button for 5 seconds to enter the "Energy-saving mode". Press and hold the "OK" button again for 5 seconds to exit the "Energy-saving mode". Energy saving mode just turns off the digital tube and LED indicator, and other functions are normal.   Function mode:  F-01 After power-on, the motor is forward T1 time; then the motor stops T3 time; then the motor reverse T2 time; so it is repeated Nx times. When the STOP port is triggered, the motor stops working immediately. (FWD, REV port is invalid)    F-02 This function is a F-01 variant. F-01 is run directly after power-on, but F-02 needs to trigger FWD or REV port to run.    F-11(Trigger  reversible 1) Trigger the FWD port, the motor is forward T1 time, and automatically stops (in order to protect the motor, during the delay period, trigger the REV port to stop T3 time and then reverse T2 time, trigger FWD port to re-time T1). Trigger the REV port, the motor is reverse T2 time, and automatically stops (in order to protect the motor, during the delay period, the FWD port is triggered to stop the T3 time and then the T1 time is forward, and the REV port is re-timed T2). When the STOP port is triggered, the motor stops immediately, regardless of whether the motor is forward or reverse.     F-12(Trigger  reversible 2) Trigger the FWD port, the motor is forward T1 time and stops automatically (during the delay period, except for triggering STOP port, the other ports are invalid). Trigger the REV port, the motor is reverses T2 time, and automatically stops (during the delay period, except for triggering STOP port, the other ports are invalid). When the STOP port is trigger, the motor stops immediately, regardless of whether the motor is forward or reverse.     F-21 When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops. When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops. In this mode, the FWD and REV ports cannot be connected low level at the same tim
  • هوية Fruugo: 415389671-876936588
  • EAN: 8461339294249

التسليم والرد

يُرسل خلال 24 ساعة

  • STANDARD: ١٥٫٩٩ ر.س.‏ - التسليم بين الاثنين 20 أكتوبر 2025 – الأربعاء 29 أكتوبر 2025

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Room201,AreaB,No.280,Zhongshan Avenue East
  • Huangpu
  • Guangzhou
  • Guangdong
  • China
  • 518000
  • firzen.pan@gmail.com
  • +8619128656319

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • +34910602659