70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

١٣٩٫٠٠ ر.س.‏
+ ٢٧٫٩٩ ر.س.‏ الشحن

70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

  • العلامة التجارية: Unbranded

70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

  • العلامة التجارية: Unbranded
السعر: ١٣٩٫٠٠ ر.س.‏
البائع:
١٣٩٫٠٠ ر.س.‏
+ ٢٧٫٩٩ ر.س.‏ الشحن

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Item Type: Blood Oxygen Probe <br>Material: Plastic <br>Applicable for CSI models, others are not applicable <br>Specification: LED 660nm/905nm/940nm <br>Maximum Output Power: 15 mw <br>Suitable for Adults with a weight >40kg, clamped on the index finger or any finger. <br> <br>Spo2 Test Range: 70%~100% <br>Spo2 Test Accuracy: ±2% when 90%~100%, ±3% when 70%~89% <br>Pulse Rate Test Range: 30~245 bpm <br>Pulse Rate Test Accuracy: ±3 bpm <br>Main Structure: Consists of plug, cable and probe <br>Application: Used for pulse oximeters and multi-parameter monitors to continuously and non-invasively collect and transmit the pulse and oxygen saturation signals of patients (adults with a body weight >40kg); not suitable for weak perfusion and exercise conditions Monitoring, the probe is not suitable for long-term monitoring, it should be checked every 4 hours or measured with 2 fingers. <br> <br>Contraindications: Do not fix this product in a location where the patient has tissue damage; it is not suitable for patients and users who are allergic to PVC, TPU, TPE, ABS plastics. <br> <br>Warning: <br>A) Improper use will cause inaccurate measurement. <br>B) When the light is too strong, the measurement will be inaccurate. In some cases, a piece of opaque material should be used to shade the light around the sensor. <br>C) The blood oxygen saturation probe should be moved to a new location at least every 4 hours. Because local skin conditions will affect the ability of the skin to withstand the placement of the probe, it is necessary to change the position of the sensor frequently according to the conditions of some patients. If the integrity of the skin changes, the probe needs to be moved to another location. <br>D) Dye in the blood vessel will cause inaccurate measurement. <br>E) The performance of the probe is easily affected by activities, so it is not suitable for active patients. <br>F) Do not use straps to fix the probe or tie it to death, because venous pulsation will cause inaccurate saturation measurement. <br>G) Like other armarium, cables should be placed so as not to entangle or suffocate the patient. <br>H) Do not use during MRI scan. Because the conductor current will cause burns. Moreover, the blood oxygen saturation probe will affect the MRI image, and the MRI device will also affect the accuracy of the blood oxygen measurement. <br>I) Do not change or modify this product at will. Because this will affect its performance or accuracy. <br>J) Do not use radiation, steam or ethylene oxide for degassing. <br>K) Do not immerse the product in liquid for cleaning and degassing. <br>L) Mobile phones or mobile RF communication equipment will affect the operation of this sensor. <br> <br>How to Use: <br>1) Place your index finger on the sensor window of the pulse oximetry probe, and touch the stop button at the end of your finger. <br>2) If the nail is too long, it will affect the fingertip to touch the stop button. <br>3) Open the lower cover of the finger clamp of the sensor to apply even force to the entire length of the gasket. Check the location of the sensor. If the index finger is placed incorrectly or cannot be used, you can use other fingers or use other types of oxygen sensors. Do not use the pulse oximetry probe on children’s thumbs or toes, or on the entire hands and feet. <br>Note: When selecting the sensor placement site, priority should be given to the limb site without arterial catheter, blood pressure cuff and venous infusion tube. <br>4) When placing the sensor, route the cable along the back of the hand. <br>5) Connect the pulse oximetry probe to the oximeter and check whether the operating procedure complies with the steps described in the operating manual. <br>Note: If the sensor cannot accurately monitor the pulse beating, it means that its position is improper or its place
  • هوية Fruugo: 379354635-818866684

التسليم والرد

يُرسل خلال 24 ساعة

  • STANDARD: ٢٧٫٩٩ ر.س.‏ - التسليم بين الجمعة 31 أكتوبر 2025 – الجمعة 07 نوفمبر 2025

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Shenzhenyuandedianziyuouxiangongsi
  • Shenzhenyuandedianziyuouxiangongsi
  • Room 1401-04 Yousuo Bldg 2000
  • Jiaxian Road Gangtou Community
  • Bantian Subdistrict
  • Shenzhen
  • China
  • 518500
  • szrhkj41@163.com
  • 15819859068

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • Huang Pengliang
  • FORCHAIN GmbH
  • Vilbeler Landstra?e73 60388 Frankfurt am Main
  • Frankfurt am Main
  • Frankfurt am Main
  • DE
  • 60388
  • nnicolesusan093@gmail.com
  • 1638127736