DT-9960H Digital Multimeter 6000-Digit LCD NCV Tester with 10A Range

٢٢٩٫٠٠ ر.س.‏
+ ٣٦٫٩٩ ر.س.‏ الشحن

DT-9960H Digital Multimeter 6000-Digit LCD NCV Tester with 10A Range

  • العلامة التجارية: Unbranded

DT-9960H Digital Multimeter 6000-Digit LCD NCV Tester with 10A Range

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ٢٨٩٫٠٠ ر.س.‏
السعر: ٢٢٩٫٠٠ ر.س.‏
أنت توفر: ٦٠٫٠٠ ر.س.‏ (20%)
البائع:
٢٢٩٫٠٠ ر.س.‏
+ ٣٦٫٩٩ ر.س.‏ الشحن

في المخزون

نقبل وسائل الدفع الآتية

الوصف

DT-9960H Digital Multimeter 6000-Digit LCD NCV Tester with 10A Range

DT‑9960H Multimeter Digital LCD Universal Tester NCV Testing with Overload Protection for Electricity Testing Item Type: Multimeter Model: DT-9960H Material: ABS Battery: 1 x 9V 6F22(battery not included) Purpose: This product can be widely used in residential, industrial factories, tenement, office buildings, home appliance equipment maintenance and testing and other industries Impact Resistance (Drop Test): 2 meters Continuity Test: if the resistance is ≤50Ω, the buzzer will sound, and the test current is <0.35mA Input Impedance: Approximately:> 10M True RMS: AC response The crest factor ≤3 can reach up to 500V at full scale, and the crest factor is reduced to ≤1.5 at 1000V Display: 6000 digit backlit LCD with analog bar graph Over Range: display "OL" Automatic Shutdown: the meter will automatically shutdown after about 15 minutes without operation (can be disabled) Polarity: automatically distinguish the polarity, (-) negative indication Measurement Speed: 3 times per second under normal conditions Fuse: mA, uA range: 800mA/1000V ceramic fast-blow A Range: 10A/1000V ceramic fast fusing Working Temperature: 0℃~50℃ (32℉~122℉) Storage Temperature: -10℃~60℃ (14℉~140℉) Working Humidity: maximum 80% at 31℃ (87℉), and linear drop to 50% at 40℃ (104℉) Storage Temperature: <80%RH Working Altitude: 2000 meters How e: 1. DC voltage measurement 1. Set the function switch to the VDC position. 3. Touch the tip of the black test lead to the negative pole of the circuit; touch the tip of the red test lead to the positive pole of the circuit. 1. Set the function switch to the V/Hz/%/VFD position and indicate "AC" on the display. Alternating current 3. Touch the tip of the black test lead to the negative pole of the circuit; touch the tip of the red test lead to the positive pole of the circuit. 5. Press and hold the MODE button for 2 seconds, "VFD" will be indicated on the display. 6. Read the VFD value on the display. 7. To exit the VFD mode, press and hold the MODE button for 2 seconds. 8. Press the Hz/% button to indicate "Hz". 9. Read the frequency on the display. 10. Press the Hz/% button again to indicate "%". 11. Read the percentage of duty cycle on the display. 1. Set the function switch to the m//Hz/% position. 2. Press the MODE button to indicate "DC" or "AC". 4. Touch the tip of the black test lead to the negative pole of the circuit; touch the tip of the red test lead to the positive pole of the circuit. 6. Press the Hz/% button to indicate "Hz". 7. Read the frequency on the display. 8. Press the Hz/% button again to indicate "%". 9. Read the percentage of duty cycle on the display. 4. Low impedance measurement 1. Set the function switch to LoZ, the LCD display will display the symbols "LoZ" and "AC". 3. Touch the tip of the black test lead to the negative pole of the circuit; touch the tip of the red test lead to the positive pole of the circuit. DC Voltage 60.00mV 0.01mV ±(0.9%+9digits) 600.0mV 0.1mV 6.000V 0.001V ±(0.5%+5digits) 60.00V 0.01V 600.0V 0.1V 1000V 1V ±(0.6%+6digits) AC Voltage(45~1kHz) 60.00mV 0.01mV ±(0.9%+9digits) 600.0mV 0.1mV 6.000V 0.001V ±(0.8%+4digits) 60.00V 0.01V 600.0V 0.1V 1000V 1V ±(0.8%+8digits) Low Impedance AC voltage 6.000V 0.001V ±(3.0%+30digits) 60.00V 0.01V 600.0V 0.1V VFD 50.0V~700V 0.1V/1V ±(4.0%+9digits) DC Current 600.0μA 0.1μA ±(1.0%+3digits) 6000μA 1μA 60.00mA 0.01mA 600.0mA 0.1mA 6.000A 0.001A ±(1.5%+3digits) 10.00A 0.1A AC Current 600.0μA 0.1μA ±(1.5%+3digits) 6000μA 1μA 60.00mA 0.01mA 600.0mA 0.1mA 6.000A 0.001A ±(2.0%+3digits) 10.00A 0.1A Resistance 600.0Ω 0.1Ω ±(1.0%+2digits) 6.000kΩ 0.001kΩ ±(0.8%+2digits) 60.00kΩ 0.01kΩ 600.0kΩ 0.1kΩ 6.000MΩ 0.001MΩ ±(1.2%+2digits) 60.00mΩ 0.01mΩ ±(1.0%+5digits) Capacitance 6.000nF 0.001nF in a relative state ±(5.0%+25digits) 60.00nF 0.01nF ±(5.0%+20digits) 600.0nF 0.1nF ±(40%+5digits) 6.000μF 0.001μF 60.00μF 0.01μF 600.0μF 0.1μF 6.000mF 0.001mF ±(10%reading) 60.00mF 0.01mF
  • هوية Fruugo: 412914620-872901038
  • EAN: 7891337004853

التسليم والرد

يُرسل خلال 24 ساعة

  • STANDARD: ٣٦٫٩٩ ر.س.‏ - التسليم بين الأربعاء 10 ديسمبر 2025 – الجمعة 19 ديسمبر 2025

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Room201,AreaB,No.280,Zhongshan Avenue East
  • Huangpu
  • Guangzhou
  • Guangdong
  • China
  • 518000
  • firzen.pan@gmail.com
  • +8619128656319

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • +34910602659