PH/ORP Water Quality Detector 0.01pH/1mV Resolution with Energy Saving LCD Backlight for Wastewater Treatment AC220V NO.0881

٧٢٤٫٠٠ ر.س.‏
والشحن مجاناً

PH/ORP Water Quality Detector 0.01pH/1mV Resolution with Energy Saving LCD Backlight for Wastewater Treatment AC220V NO.0881

  • العلامة التجارية: Unbranded

PH/ORP Water Quality Detector 0.01pH/1mV Resolution with Energy Saving LCD Backlight for Wastewater Treatment AC220V NO.0881

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ٨٧٤٫٠٠ ر.س.‏
السعر: ٧٢٤٫٠٠ ر.س.‏
أنت توفر: ١٥٠٫٠٠ ر.س.‏ (17%)
البائع:
٧٢٤٫٠٠ ر.س.‏
والشحن مجاناً

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Feature 1Continuous Measurement: PH110 industrial pH meter is an intelligent upgrade product of industrial acidity meter, which can continuously measure and control the pH value of sewage. 2Function: PH tester can perform PH/ORP measurement, upper and lower limit control, current output, and digital communication. 3LCD Backlight: LCD backlight can choose energysaving mode, and it will be automatically turned off at regular intervals. Audible alarm can be switch on and off. 4Meter Mode: ORP water quality tester has meter mode isolation and transmission port, and the maximum loop resistance is greater than 300. 5Scope of Application: PH tester is suitable for city sewage treatment plants, chemicals, printing and dyeing, papermaking, pharmaceuticals, electroplating and environmental protection and other fields.Item Type: ORP Water Quality TesterMaterial: ABSMeasuring Range: PH(0 14 pH) ;ORP( -1900 - +1900 mV)Accuracy: + 0.02 pH; + 1 mVResolution: 0.01pH; 1mVStability: 0.02 pH/24 Hours; 3 mV/24 HoursPH Standard Solution: 4.00/6.86/9.18Display Mode: 128x64 dot Array LCDTemperature Compensation: 0100 C Manual/Auto (NTC10K)Signal Output: 4-20mA Isolation Protection Output, Maximum Loop Resistance 300Alarm Output: One Set of High and Low Limit Alarm Contacts (3A/250 V AC), Normally Open Contact RelayPower Supply: AC220VPower Consumption: 3WEnvironmental Conditions: (1) Temperature 060 (2) Humidity85%RHBoundary Dimension: Approx. 96 x 96 x 110mm / 3.8 x 3.8 x 4.3in (H x W x D)Hole Size: Approx. 92 x 92mm / 3.6 x 3.6in (H x W)Electrode Length: Approx. 5meters / 5.5 ORP Electrode .wang-edit-text{ font-family:'Arial' !important; } .wang-edit-text table { border-top: 1px solid #000; border-left: 1px solid #000; } .wang-edit-text table td, .wang-edit-text table th { border-bottom: 1px solid #000; border-right: 1px solid #000; padding: 3px 5px; } .wang-edit-text table th { text-align: center; }Package List1 x ORP Water Quality Tester1 x Electrode1 x User ManualNote1. The electrode should be cleaned regularly. When disassembling and cleaning the electrode, you cannot break the oxygen permeable membrane, and you cannot use filter paper to rub the oxygen permeable membrane on the electrode to avoid damaging the oxygen permeable membrane.2. The cable connector must be kept clean, and must not be exposed to moisture or water.3. When the displayed value of the instrument differs greatly from the actual value or cannot measure the low content of oxygen, the electrolyte inside the oxygen electrode may dry up and needs to be refilled with electrolyte, generally the maintenance work of replacing or adding electrolyte is carried out once every 6 months; the spare membrane head needs to be replaced when the permeation membrane ruptures. Each time after replacing or adding electrolyte or replacing the spare membrane head, the electrode needs to be repolarized and calibrated. The specific steps are as follows: put the electrode upside down, unscrew the black part of electrode shielding at the lower part of the electrode, remove the membrane head, pour off the old liquid in the cavity, fill in the original electrolyte, do not fill it too full, and let the excess electrolyte drain off. Just screw it tightly and make sure the membrane can stick to the head of the electrode core. After replacing the electrolyte well, the polarization and calibration should be done again.4. Electrode polarization: After the electrode is connected to the instrument, it will be polarized when it is continuously energized for more than 0.5 hours, and the electrode can be calibrated only after it is polarized.
  • هوية Fruugo: 296177415-662385428
  • EAN: 7987249320881

معلومات سلامة المنتج

يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

ملصقات سلامة المنتج

CE Mark
تحذيرات السلامة: Not suitable for children under 36 months. Choking Hazard. Adult supervision recommended

التسليم والرد

يُرسل خلال ٣ أيام

  • STANDARD: مجاناً - التسليم بين الخميس 04 ديسمبر 2025 – الثلاثاء 23 ديسمبر 2025 - مجاناً

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Advance Parts Zone
  • Shenzhen Mike Technology Co. Ltd.
  • No. 108 Donghuan 1st Road
  • Yousong Technology Building 4-B01
  • Shenzhen
  • CN
  • 518000
  • miekortech@hotmail.com
  • +8613714168241

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • Ben XU
  • REP Europe GmbH
  • Annastr. 9 B
  • Griesheim
  • Germany
  • 64347
  • info@rep-europe.de
  • +4915751253212
  • http://www.rep-europe.de/